cici@tianrui-fuse.com    +86-15992941715
Cont

Have any Questions?

+86-15992941715

Jun 13, 2025

What are the 5 types of the fuses?

1.Cartridge Fuses (Glass or Ceramic Body):

Current Fuse

   1.Glass Tube (Low-Breaking Capacity - LBC): Ubiquitous cylindrical fuse design featuring a transparent glass tube enclosing a calibrated fuse element (typically tin-plated copper or silver alloy wire/ribbon) embedded in arc-quenching filler (often silica sand). Primarily utilized in low-energy AC circuits (e.g., appliances, electronics) up to 600V AC, with interrupting ratings typically below 10kA. Visibility of the severed element aids visual inspection.
 

   2.Ceramic Body (High-Breaking Capacity - HBC/HRC): Engineered for demanding applications. Features a robust ceramic tube body filled with high-purity quartz sand. The precisely calibrated silver or silver-chromium fuse element ensures controlled arc extinction under high fault currents (interrupting ratings from 35kA to 200kA+). Standardized in dimensions (e.g., DIN 43620, IEC 60269). Essential for industrial power distribution, motor control centers (MCCs), and service entrance protection.
 

2.Blade Fuses (Automotive - ATO®, ATC®, MINI®, MICRO2/3®, LP-MINI):

Auto Fuse

   1.Industry-standard flat plastic-bodied fuses with integral male blade terminals designed for plug-in fuse blocks/holders. Color-coding per amperage rating per ISO 8820-3. Engineered for the harsh environment of automotive and mobile equipment (12V/24V/42V DC systems), offering vibration resistance and ease of service. Variants (MINI, MICRO) address increasing space constraints and power demands in modern vehicles. Low voltage DC interruption is a key design focus.
 

3.Resettable Fuses (Polymeric PTC - Positive Temperature Coefficient):

   1.Formally termed PPTC devices. Solid-state, non-linear thermistors composed of conductive polymer composite. Under normal current, low resistance. During an overcurrent, I²R heating causes a rapid, dramatic increase in resistance ("trip"), limiting current to a low leakage value. Upon fault removal and cooldown, they reset to low resistance. Characterized by hold current (Ih), trip current (It), maximum voltage (Vmax), and trip time. Crucial for protecting sensitive electronics (PCBs, battery packs, USB ports) against overcurrent and overtemperature where field replacement is impractical. Not suitable for high-energy fault protection.
 

4.Time-Delay (Dual-Element) Fuses:

   1.Specifically engineered to withstand harmless transient overloads (e.g., motor inrush currents, transformer energization) while providing fast protection against sustained overloads and short-circuits. Achieved via a dual-element design: a spring-loaded short-circuit element and a thermal overload element (often a solder joint or M-effect pellet). Key specifications include rated current (In), time-delay characteristics (e.g., "T" rating per UL 248), and interrupting rating. Mandatory for motor branch circuit protection (NEC Article 430), transformer primaries, and capacitor banks.
 

5.High Rupture Capacity (HRC) / High-Performance Current-Limiting Fuses:

Fuse link and fuse base

   1.Representing the pinnacle of fuse protection technology for medium/high voltage (up to 40.5kV AC/DC) and extreme fault currents. Feature robust ceramic or molded epoxy bodies packed with high-grade silica sand arc-quenching media and precisely engineered silver or silver-alloy elements (often with notch points or complex geometries). Engineered to:
 

         1.Interrupt fault currents well before the first current zero (current-limiting action).
         2.Withstand extremely high prospective fault currents without rupture (interrupting ratings exceeding 100kA RMS Sym).
         3.Generate very low let-through I²t and Ip (Peak Current), protecting downstream equipment.
         4.Comply with stringent standards (IEC 60269, IEEE/ANSI C37.46, BS 88). Indispensable in power distribution networks, substations,                              renewable energy converters (especially DC side), UPS systems, and large industrial drives.

 

Critical Selection Factors (Beyond Type): Selecting the appropriate fuse requires rigorous analysis of:

  • System Voltage (AC/DC): Must exceed maximum circuit voltage (Vrated > Vsystem).
  • Normal Operating Current (In): Fuse In must exceed the circuit's continuous full-load current, considering ambient temperature derating.
  • Available Fault Current (Prospective Isc): Fuse interrupting rating (IEC Icu / UL IR) must exceed the calculated maximum prospective fault current at the point of installation.
  • Required Protection Characteristic: Fast-acting (F) vs. Time-Delay (T) vs. Ultra-Rapid (for semiconductors).
  • Let-Through Characteristics (I²t, Ip): Critical for coordination and downstream equipment protection, especially with HRC fuses.
  • Application-Specific Standards: UL 248, IEC 60269, ANSI C37.46, ISO 8820, etc.
  • Physical Requirements & Mounting: Dimension standards, blade type, bolt-on, clips, etc.
  • Environmental Conditions: Ambient temperature, altitude, vibration, humidity.

Send Inquiry